Preliminary study on the diagnostic value of acoustic radiation force impulse technology for differentiating between benign and malignant thyroid nodules

84Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives-This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions. Methods-Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging (VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the X2 test were used to compare the elastic parameters. Results-Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values ± SD of 2.034 ± 0.484, 1.835 ± 0.364, 2.293 ± 0.787, and 3.941 ± 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P< .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001). Conclusions- Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications. ©2012 by the American Institute of Ultrasound in Medicine.

Cite

CITATION STYLE

APA

Gu, J., Du, L., Bai, M., Chen, H., Jia, X., Zhao, J., & Zhang, X. (2012). Preliminary study on the diagnostic value of acoustic radiation force impulse technology for differentiating between benign and malignant thyroid nodules. Journal of Ultrasound in Medicine, 31(5), 763–771. https://doi.org/10.7863/jum.2012.31.5.763

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free