Abstract
This article presents a pictorial representation of a generalized model for a human interacting with an exoskeleton or a force-augmenting device. This model is used for comparing four different control schemes, which are: 1) Kazerooni's algorithm, 2) BLEEX’s algorithm, 3) technique inspired by fictitious gain, and 4) Force control with velocity and position feedback. The hardware and software requirements for the presented control algorithms are also discussed.
Cite
CITATION STYLE
Concha, A., González-Sánchez, F. E., Ramírez-Velasco, E., Sánchez, M., & Gadi, S. K. (2018). Comparison of Control Algorithms Using a Generalized Model for a Human with an Exoskeleton. Journal of Applied Science & Process Engineering, 5(1), 249–255. https://doi.org/10.33736/jaspe.408.2018