This research will be conducted in accordance with Indonesian Standard SK SNI and foreign standard ASTM. The test object consists of a cylindrical test with the diameter of 15 cm and a height of 30 cm, and it is developed to 4 mixture variations with the amount of 2%, 4%, 6%, 8%, of total cement. The mechanical properties of concrete is being tested include concrete compressive strength. Itis tested at the age of 7 days, and then converted at 28 days, using test objects mixed with different fiber variations. The results of the test are: compressive strength test with 2% variation is 7,54MPa, compressive strength testwith 4% variation is 6,74 Mpa, compressive strength with 6% variation is 4,58 Mpa, compressive strength with 8% variation is 3.63 MPa. Maximum concrete compressive strength occurs in 2% fiberĀ mixture, while the minimum concrete compressive strength occurs in 8%. From these results, it can be concluded that the addition of water hyacinth fiber to the mixture for low quality concrete has not been able to increase its compressive strength.Keywords: Fiber, Water Hyacinth, Concrete Compressive Strength.
CITATION STYLE
Affandy, N., & Lubis, Z. (2018). PENGARUH PENAMBAHAN SERAT ALAMI ECENG GONDOK TERHADAP KUAT TEKAN BETON BERKUALITAS RENDAH. UKaRsT, 2(1), 10. https://doi.org/10.30737/ukarst.v2i1.262