Feasibility of High-Dose Dobutamine Stress SSFP Cine MRI at 3 Tesla with Patient Adaptive Local RF Shimming using Dual-Source RF Transmission: Initial Results

  • Strach K
  • Clauberg R
  • Müller A
  • et al.
N/ACitations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

PURPOSE: To investigate the feasibility of high-dose dobutamine stress (HDDS) imaging using SSFP sequences at 3 T employing patient-adaptive local RF-shimming using a dual-source RF transmission system.MATERIALS AND METHODS: 13 Patients underwent a HDDS protocol on a 3 T MRI scanner (Achieva 3.0T-TX, Philips Healthcare), equipped with a dual-source RF transmission system. SSFP cine sequences using patient-adaptive local RF-shimming (RF-S) were compared to cine images acquired without additional shimming. Image quality was evaluated on a 4-point grading scale and number of non-diagnostic segments assessed. Contrast (CN) between myocardium (SIM) and blood pool (SIB) was calculated [(SIB-SIM)/(SIB+SIM)].RESULTS: Image quality both at rest and maximum stress was significantly improved with RF-S (ED:3.56±0.5 vs. 3.23±0.63; ES:3.4±0.5 vs. 3.1±0.7) compared to no RF-S (ED:2.9±0.72 vs. 2.15±0.78; ES:2.64±0.74 vs. 1.95±0.76; p<0.01). The amount of non-diagnostic segments was significantly reduced when using RF-S at rest and stress (3 vs. 39; 19 vs. 78, p<0.05). All HDDS studies were diagnostic if performed with RF-S (n=13/13) in comparison to conventional shimming (n=5/13). Image contrast was improved for SSFP sequences with RF-S (0.53±0.08) compared to conventional images (0.46±0.09, p=0.06).CONCLUSION: Patient-adaptive local RF-shimming using a dual-source RF transmission system allows for reliable SSFP imaging in a clinical high-dose dobutamine stress protocol at 3 T. RF-S significantly improves image quality and reduces the number of non-diagnostic myocardial segments.

Cite

CITATION STYLE

APA

Strach, K., Clauberg, R., Müller, A., Wonneberger, U., Naehle, C., Kouwenhoven, M., … Thomas, D. (2012). Feasibility of High-Dose Dobutamine Stress SSFP Cine MRI at 3 Tesla with Patient Adaptive Local RF Shimming using Dual-Source RF Transmission: Initial Results. RöFo - Fortschritte Auf Dem Gebiet Der Röntgenstrahlen Und Der Bildgebenden Verfahren, 185(01), E3–E3. https://doi.org/10.1055/s-0032-1330523

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free