Effect of laser-microtexturing on bone and soft tissue attachments to dental implants: A systematic review and meta-analysis

6Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

Abstract

Background. It is critical to understand laser-microtextured implant collars’ influence on periimplant pocket depths and marginal bone levels, especially in crucial areas. The present review investigated the peri-implant marginal bone loss (MBL) and pocket depths and failure rates of dental implants with laser-microtextured collars. Methods. An electronic search was run in the PubMed and Embase databases until September 15, 2019. Randomized and prospective clinical studies comparing peri-implant MBL and pocket depths and failure rates between implants with laser-microtextured and machined collar surfaces were included. Five studies (two cohort studies and three RCTs) were included in the meta-analysis after the inclusion and exclusion criteria and qualitative assessments were applied. The risk ratio of osseointegrated implant failure and mean differences in peri-implant MBL and pocket depths were calculated using the Comprehensive Meta-Analysis (CMA) software. Results. Implants with laser-microtextured collars exhibited significantly better marginal bone level scores (P < 0.001; MD: 0.54; 95% CI: 0.489‒0.592) and a significant reduction in peri-implant probing depths than implants with machined collars (P < 0.001; MD: 1.01; 95% CI: 0.90‒1.13). The assessed studies showed that 17 out of 516 implants failed (3.29%), comprising nine implants with machined (3.62%) and eight implants with laser-microtextured collars (2.98%). However, no significant differences were detected in the implant neck surface characterization (P = 0.695; RR: 1.205; 95% CI: 0.472‒3.076). Conclusion. This study suggests that laser-microtexturing of implant collar significantly affected the peri-implant MBL and probing depths. Although no significant differences were noted in implant failure rates between implants with laser-microtextured and machined collar surfaces, the peri-implant MBL and probing depths with laser-microtextured collars were significantly lower than the machined collars.

Cite

CITATION STYLE

APA

Koodaryan, R., & Hafezeqoran, A. (2021). Effect of laser-microtexturing on bone and soft tissue attachments to dental implants: A systematic review and meta-analysis. Journal of Dental Research, Dental Clinics, Dental Prospects, 15(4), 290–296. https://doi.org/10.34172/joddd.2021.048

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free