Relative Error between Organ Doses and Size-specific Dose Estimates for a Specific Location When the Mean CTDI vol Value Is Used for Calculation

  • Dendo Y
  • Abe K
  • Onodera S
  • et al.
N/ACitations
Citations of this article
3Readers
Mendeley users who have this article in their library.

Abstract

Size-specific dose estimates (SSDEs) are dose indices that account for differences in body shape in computed tomography (CT) scans, allowing the evaluation of approximate absorbed doses in any cross section that could not be obtained with the volume CT dose index (CTDI(vol)). When using automatic exposure control (AEC), CTDI(vol) is modulated in the body axis direction, but the value displayed after the examination is the mean CTDI(vol) for the entire scan, and it is expected that the SSDE value will change depending on which value is used in the calculation. In this study, using a human body phantom, we examined the influence of whether the mean CTDI(vol) or the modulation value for each slice is used to calculate the SSDE on local organ dose evaluation. A program to calculate water equivalent diameter according to the procedure in the American Association of Physicists in Medicine Report No. 220 was developed and compared. As a result, SSDE calculated using the mean CTDI(vol) (local-SSDE(mean)) overestimated organ doses in the lung region by 18%-56% compared with those calculated by a web system for evaluating CT exposure doses (WAZA-ARIv2, Japan). In contrast, local-SSDE(modulated), which was calculated using the modulated value of the CTDI(vol), was able to estimate the organ dose with a relative error of 10%-13%. The average local-SSDE over the entire body axis direction was not significantly different between the two methods, regardless of which method was used for CTDI(vol). If the mean CTDI(vol) is stored in the Digital Imaging and Communications in Medicine (DICOM) header tag (0018, 9345) of the CT image and the modulated CTDI(vol) value is not available for each slice, the calculated local SSDE will contain many errors and will not correctly reflect the organ doses at the scan region. In such cases, it is available to use the method of evaluating local organ doses by multiplying the SSDE, which is the average of the SSDE for the entire scan, by a factor for each organ.

Cite

CITATION STYLE

APA

Dendo, Y., Abe, K., Onodera, S., & Kayano, S. (2023). Relative Error between Organ Doses and Size-specific Dose Estimates for a Specific Location When the Mean CTDI vol Value Is Used for Calculation. Japanese Journal of Radiological Technology, 79(12), 1375–1384. https://doi.org/10.6009/jjrt.2023-1373

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free