Accuracy and reproducibility of visual coronary stenosis estimates using information from multiple observers

17Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The reliability of visual estimation of severity of coronary artery stenosis may be improved using data from multiple independent observers. Data were collected from the results of a video format examination used on an experimental basis in 1987 by the American Board of Internal Medicine to test 61 candidates for certification in cardiovascular diseases. Twenty arteriographic cases were presented in a standardized format. Each artery was viewed in multiple projections including angled views. Each view was shown in both real time and slow motion, and each case was seen twice in its entirety. The observers rated stenosis severity on a four‐point scale ranging from 1–4. A two‐way repeated measures analysis of variance was performed on the tabulated results, yielding variance components for the arteriographic data (signal), the differences among observers, and the observer by case interaction (both considered noise). These components then allowed calculation of 68 and 95% confidence intervals, the signal‐to‐noise ratio, and the reproducibility coefficient for any number of observers. When a single observer was considered, reproducibility was low, with 95% confidence intervals of ± 0.9 points, corresponding to approximately ± 22% diameter stenosis. However, when data of three observers were averaged, the 95% confidence interval decreased to ± 0.52 points (13% stenosis), signal‐to‐noise ratio rose to 12.2, and reproducibility coefficient was 0.92. Relatively small increments in these values were noted when data from a fourth or fifth observer were added. In comparison to a computer‐assisted quantitative method, 86% accuracy was found for the results of averaged subjective determinations of stenosis severity. These data indicate that the reliability of visual estimation of coronary stenosis severity may be increased to acceptable levels by use of data from as few as three observers. Averaging of estimates from several independent observers should be reconsidered as a practical method which has the potential to realize considerable cost savings in the interpretation of coronary arteriograms. Copyright © 1992 Wiley Periodicals, Inc.

Cite

CITATION STYLE

APA

Kussmaul, W. G., Popp, R. L., & Norcini, J. (1992). Accuracy and reproducibility of visual coronary stenosis estimates using information from multiple observers. Clinical Cardiology, 15(3), 154–162. https://doi.org/10.1002/clc.4960150305

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free