Abstract
Introduction The standard arterial system for blood withdrawal provides no impediment to intra-arterial injection [1] and bacterial contamination. We assessed the probability of inadvertent intra-arterial injection, transmission of bacterial contamination and surveyed the nursing stafffollowing introduction of a non-injectable connector (NIC). Methods The simulation study data were descriptive. Fifteen junior doctors managed a case of bradycardia. A simulated patient had a peripheral intravenous cannula, central venous catheter and brachial arterial cannula. Atropine was available on request. A laboratory controlled trial compared a transmission of bacteria through standard arterial ports against the NIC when attached to an arterial sampling hub. The colonization rates were compared using a two-tailed Fisher's exact test. A closed-circuit arterial sampling system was designed. A contaminated syringe tip was inserted into the conventional arterial hub or the NIC to take an arterial sample. Transducer flush fluid flowing to the patient bloodstream was cultured. In a survey the nursing staffwere asked questions regarding the NIC system, including its manual handling, sampling of the blood and its durability. Results In the simulation study 10/15 clinicians (67%) injected atropine directly into arterial cannula via a three-way tap. Five of 15 doctors (34%) injected safely. In the laboratory study, swabbing of the arterial hubs showed bacterial contamination of all of the samples in the standard group (20/20) and no contamination in the NIC group (0/20), P <0.0001. Eighty-five per cent (17/20) of samples in the standard arterial group showed onward transmission of pathogens to the patient circulation, and none of the patient samples taken from the NIC group were contaminated (0/20), P <0.0001. In the survey, 80% of the nurses found manual handling of a new device equally simple and 20% even simpler. Sampling of the blood was equally challenging for 87% participants. Ninety-four per cent found similar durability of the new device and better protection against accidental intra-arterial injection. Sixty-six per cent of the nursing staffwould replace the standard system with a NIC. Conclusion Most of the doctors would inject the drug intra-arterially. Currently, no other device is available to eliminate accidental intraarterial injection or bacterial transmission. The nursing stafffound the management of the NIC equally challenging.
Cite
CITATION STYLE
Laba, D., Mariyaselvam, M., Heij, R., & Young, P. (2014). Introducing an arterial non-injectable connector into clinical practice. Critical Care, 18(S1). https://doi.org/10.1186/cc13278
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.