Pivotal Study of a Next-Generation Balloon-Expandable Stent-Graft for Treatment of Iliac Occlusive Disease

55Citations
Citations of this article
60Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To evaluate the safety and efficacy of a next-generation balloon-expandable stent-graft for the treatment of arterial occlusive disease in patients with de novo or restenotic lesions in the common and/or external iliac arteries. Methods: A prospective, multicenter, single-arm safety and efficacy study (ClinicalTrials.gov identifier: NCT02080871) of the VBX Stent Graft for treatment of de novo or restenotic lesions in the iliac arteries was conducted under an Investigational Device Exemption at 26 US sites and 1 New Zealand center. The study eligibility criteria were established with the aim of enrolling more "real-world" patients compared with previous iliac stent studies supporting Food and Drug Administration approval. The study enrolled 134 patients (mean age 66±9.5 years; 79 men) with 213 iliac lesions. Three-quarters of the population (101, 75.4%) had Rutherford category 3 ischemia, and 43 (32.1%) patients presented with TASC II C/D lesions. The primary endpoint was a composite of device- or procedure-related death within 30 days, myocardial infarction within 30 days, target lesion revascularization (TLR) within 9 months, and amputation above the metatarsals in the treated leg within 9 months. Results: In all, 234 devices were implanted in 213 lesions with 100% technical success; 57 (42.5%) patients received kissing stents at the aortic bifurcation. No devices exhibited a discernable change in length after final deployment as determined by independent core laboratory quantitative angiographic analysis. At 9 months, 3 (2.3%) of 132 patients (1 lost to follow-up, 1 unrelated death) experienced a major adverse event (3 TLRs) related to the primary endpoint. At 9 months, there were no device-related serious adverse events or unanticipated adverse device effects. Conclusion: The next-generation balloon-expandable stent-graft demonstrated notable 9-month safety and efficacy in treating iliac occlusive disease in patients reflecting common clinical practice.

Cite

CITATION STYLE

APA

Bismuth, J., Gray, B. H., Holden, A., Metzger, C., & Panneton, J. (2017). Pivotal Study of a Next-Generation Balloon-Expandable Stent-Graft for Treatment of Iliac Occlusive Disease. Journal of Endovascular Therapy, 24(5), 629–637. https://doi.org/10.1177/1526602817720463

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free