Abstract
As single tunneling magnetoresistive (TMR) sensor performance in modern high-speed applications is limited by breakdown voltage and saturation of the sensitivity, for higher voltage applications (i.e., compatible to 1.8 V, 3.3 V or 5 V standards) practically only a series connection can be applied. Thus, in this study we focused on sensitivity, 3 dB bandwidth and sensitivity-bandwidth product (SBP) dependence on the DC bias voltage in single and series-connected TMR sensors. We show that, below breakdown voltage, the strong bias influence on sensitivity and the 3 dB frequency of a single sensor results in higher SBP than in a series connection. However, the sensitivity saturation limits the single sensor SBP which, under 1 V, reaches the same level of 2000 MHz·V/T as in a series connection. Above the single sensor breakdown voltage, linear sensitivity dependence on the bias and the constant 3 dB bandwidth of the series connection enable increasing its SBP up to nearly 10, 000 MHz · V/T under 5 V. Thus, although by tuning bias voltage it is possible to control the sensitivity-bandwidth product, the choice between the single TMR sensor and the series connection is crucial for the optimal performance in the high frequency range.
Author supplied keywords
Cite
CITATION STYLE
Dąbek, M., Wisńiowski, P., Stobiecki, T., Wrona, J., Cardoso, S., & Freitas, P. P. (2016). Sensitivity and 3 dB bandwidth in single and series-connected tunneling magnetoresistive sensors. Sensors (Switzerland), 16(11). https://doi.org/10.3390/s16111821