Does the Choice of Spinal Interbody Fusion Approach Significantly Affect Adjacent Segment Mobility?

8Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Study Design.Biomechanical study of range of motion (ROM) at the vertebral levels adjacent to the construct of posterior pedicle screw-rod fixation with different types of lumbar interbody fusion techniques (LIF).Objective.To investigate the differences in adjacent segment mobility among three types of LIF: lateral lumbar interbody fusion (LLIF), transforaminal lumbar interbody fusion (TLIF), and posterior lumbar interbody fusion (PLIF).Summary of Background Data.Previous studies have concluded that LLIF, TLIF, and PLIF with posterior pedicle screw-rod fixation (PSR) provide equivalent stability in cadaveric specimens and are comparable in fusion rate and functional outcome. However, long-term complications, such as adjacent segment degeneration associated with each type of interbody device, are currently unclear. Little is known about the biomechanical effects of interbody fusion technique on the mobility of adjacent segments.Methods.Normalized ROM data at the levels adjacent to L3-L4 PSR fixation with three different types of lumbar interbody fusion approaches (LLIF, TLIF, and PLIF) were analyzed. Intact (n = 21) and instrumented (n = 7 per group) L2-L5 cadaveric specimens were tested multidirectionally under pure moment loading (7.5 Nm). Analysis of variance of adjacent segment ROM among the groups was performed. Statistical significance was set at P < 0.05.Results.Normalized ROM was significantly greater with PLIF than with LLIF in all directions at both proximal and distal adjacent segments (P ≤ 0.02) except for axial rotation at the distal adjacent segment (P = 0.07). TLIF also had greater normalized ROM than LLIF during lateral bending at the proximal adjacent segment (P = 0.008) and during flexion, extension, and lateral bending at the distal adjacent segment (P ≤ 0.03). Normalized ROM was not significantly different between PLIF and TLIF.Conclusion.The choice of lumbar interbody fusion approach influences adjacent segment motion in a cadaveric model. LLIF had the least adjacent segment motion.Level of Evidence: 3.

Cite

CITATION STYLE

APA

Wangsawatwong, P., Sawa, A. G. U., Pereira, B. D. A., Lehrman, J. N., Turner, J. D., Uribe, J. S., & Kelly, B. P. (2021). Does the Choice of Spinal Interbody Fusion Approach Significantly Affect Adjacent Segment Mobility? Spine, 46(21), E1119–E1124. https://doi.org/10.1097/BRS.0000000000004058

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free