ANALISA PENGARUH LAJU ALIRAN FLUIDA AIR PADA SALURAN PIPA AHU (AIR HANDLING UNIT) TERHADAP CAPAIAN SUHU OPTIMUM MESIN PENDINGIN MINI WATER CHILER

  • Kayana M
  • Nugraha I
  • Dantes K
N/ACitations
Citations of this article
53Readers
Mendeley users who have this article in their library.

Abstract

Penelitian ini Penelitian ini bertujuan untuk mengetahui variasi laju aliran fluida air terhadap capaian suhu optimal mesin pendingin Mini Water Chiler yang di hasilkan pada siklus sekunder. Adapun variasi laju aliran fluida air yang digunakan yaitu variasi laju aliran air 0,27 liter/detik, 0,55 liter/detik, dan 0,83 liter/detik..pengumpulan data pada penelitian ini dilakukan setiap 20 menit sebanyak 20 kali. Dari hasil penelitian didapatkan penggunakan variasi laju aliran fluida air 0,27 liter/detik,0,55 liter/detik, dan 0,83 liter/detik pada AHU 1 adalah 26,430C : 19,330C : 13,430C. Pada AHU 2 adalah 26,330C : 19,22 0C : 13,330C. Pada AHU 3 adalah 26,230C : 19,120C : 13,230C. Dari pengujian di atas didapatkan penggunaan laju aliran fluida air 0,83 liter/detik menghasilkan suhu paling optimal dibandingkan dengan laju aliran fluida air 0,27 liter/detik dan 0,55 liter/detik, hal ini disebabkan semakin cepat laju aliran fluida air maka semakin optimal suhu yang di capai Mini Water Chiller  dan penyerapan panas pada setiap ruangan akan menjadi maksimal.Kata Kunci : Mini Water Chiler, Laju Aliran Fluida, Capaian Suhu OptimalThis study tries to study the variation of air fluid flow to the optimal temperature of Mini Water Chiler cooling machines produced in the secondary cycle. The variations in the air flow rate of the air used are variations in air flow rates of 0.27 liters / second, 0.55 liters / second, and 0.83 liters / second. The data analysis technique in this study uses one-way variation analysis. Data collection in this study was carried out every 20 minutes 20 times. From the results of the study obtained using variations in air fluid flow rate 0.27 liters / second, 0.55 liters / second, and 0.83 liters / second in AHU 1 is 26.430C: 19.330C: 13.430C. In AHU 2 is 26.330C: 19.22 0C: 13.330C. In AHU 3 is 26.230C: 19.120C: 13.230C. The water flow of 0.83 liters / second produces an optimal flow of water fluid 0.27 liters / second and 0.55 liters / second, this results in increased fluid flow velocity then the optimal temperature achieved by the Mini Water Chiller and heat at each the room will be maximal.Keywords: Mini Water Chiler, Fluid Flow Rate, Optimal Temperatur Achievement

Cite

CITATION STYLE

APA

Kayana, M. D., Nugraha, I. N. P., & Dantes, K. R. (2019). ANALISA PENGARUH LAJU ALIRAN FLUIDA AIR PADA SALURAN PIPA AHU (AIR HANDLING UNIT) TERHADAP CAPAIAN SUHU OPTIMUM MESIN PENDINGIN MINI WATER CHILER. Jurnal Pendidikan Teknik Mesin Undiksha, 7(3), 129–134. https://doi.org/10.23887/jptm.v7i3.26517

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free