An attempt is made to design, fabricate and test a miniature heat pipe with 5 mm diameter and 150 mm length with a thermal capacity of 10 W. Experiments were conducted with and without working fluid for different thermal loads to assess the performance of heat pipe. The working fluids chosen for the study were same as those commonly used namely, water, methanol and acetone. The temperature distribution across the heat pipe was measured and recorded using thermocouples. The performance of the heat pipe was quantified in terms of thermal resistance and overall heat transfer coefficient. The amount of liquid filled was varied and the variation of the performance parameters for varying liquid inventory is observed. Finally, optimum liquid fill ratio is identified in terms of lower temperature difference and thermal resistance and higher heat transfer coefficient. The data reported in this study will serve as a good database for the researchers in this field. Overall heat transfer coefficient of the Miniature heat pipe is found to be the maximum for the Acetone as working fluid.DOI: http://dx.doi.org/10.3329/jme.v41i2.7473

Cite

CITATION STYLE

APA

Mozumder, A. K., Akon, A. F., Chowdhury, M. S. H., & Banik, S. C. (2011). PERFORMANCE OF HEAT PIPE FOR DIFFERENT WORKING FLUIDS AND FILL RATIOS. Journal of Mechanical Engineering, 41(2), 96–102. https://doi.org/10.3329/jme.v41i2.7473

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free