CT-Based 3D Reconstruction of Lower Limb Versus X-Ray-Based 3D Reconstruction: A Comparative Analysis and Application for a Safe and Cost-Effective Modality in TKA

8Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Aim: Patient Specific Instrumentation (PSI) with 3D bone models have been used to improve the outcomes of Total Knee Arthroplasty (TKA). The PSI, however, needs a CT (Computed tomography)/MRI scan to reproduce a bone-based model. However, CT is not a routine imaging method in the TKA and has challenges such as high radiation exposure and increased investigation cost. Any technology or software which could accurately recreate 3D bone models using X-ray would be a cheaper and safer tool. This study is based on one such technology (XrayTo3D®) using X-ray to 3D as an alternative to other image-based 3D bone models and PSI available in the market. This study compares the accuracy of XrayTo3D® versus a Conventional CT to 3D, in the reconstruction of lower limb bones (femur and tibia). Method: In an analysis of 45 lower limbs, 11 anatomical parameters were measured [Medial Proximal Tibial Angle—MPTA, Tibial(T)-torsion, T-slope, T-length, Mechanical Lateral Distal Femoral Angle (mLDFA), F-version, F-length, Distal femoral Medio lateral width (F-ML), Distal Femoral Antero Posterior (F-AP), Proximal Tibia Antero Posterior (T-AP), Proximal Tibia Medio Lateral (T-ML) based on landmarks selected by three orthopaedic surgeons(numbers of the authors superscript), on two groups of 3D models, one reconstructed using XrayTo3D® and the other using CT. Mean and standard-deviation values were measured for all the parameters in both the groups. Statistical association between both the groups was measured by Pearson's correlation coefficient. Two-sided t tests of the mean values were calculated to compare the two measurement methods. The interobserver reproducibility within each group was measured by the intraclass correlation coefficient (ICC). Point-to-surface (P2S) error, in the distal femur and proximal tibia regions of the models reconstructed using XrayTo3D®, were also measured. Results: For all the 11 parameters, no statistically significant difference was found between the 2 groups (p > 0.05). Pearson's correlation coefficients for all the parameters were not significant. The interobserver reproducibility was ranging from 0.90 to 1.00 and 0.90 to 1.00 for the XrayTo3D® and CT groups, respectively. The mean P2S distance was 1.0 mm in distal femur and 1.1 mm in proximal tibia which was within the acceptable limits. Conclusion: The reconstruction accuracy of the XrayTo3D® is an accurate, safe and cost effective as compared to a CT-based method.

Author supplied keywords

Cite

CITATION STYLE

APA

Shetty, V., Wagh, Y., Karade, V., Maurya, A., Parihar, M., Shekhar, S., & Tandel, J. (2021). CT-Based 3D Reconstruction of Lower Limb Versus X-Ray-Based 3D Reconstruction: A Comparative Analysis and Application for a Safe and Cost-Effective Modality in TKA. Indian Journal of Orthopaedics, 55(5), 1150–1157. https://doi.org/10.1007/s43465-021-00456-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free