Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance

10Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Methicillin-resistant Staphylococcus aureus (MRSA) is a human pathogen, representing an infection control challenge. Conventional MRSA screening takes up to three days, therefore development of rapid detection is essential. Real time-PCR (rt-PCR) is the fastest method fulfilling this task. All currently published or commercially available rt-PCR MRSA assays relay on single or double-locus detection. Double-locus assays are based on simultaneous detection of mecA gene and a S. aureus-specific gene. Such assays cannot be applied on clinical samples, which often contain both coagulase-negative staphylococci (CoNS) and S. aureus, either of which can carry mecA. Single-locus assays are based on detection of the staphylococcal cassette chromosome mec (SCCmec) element and the S. aureus-specific orfX gene, assuming that it is equivalent to mecA detection. Findings. Parallel evaluation of several published single and double-locus rt-PCR MRSA assays of 150 pure culture strains, followed by analysis of 460 swab-derived clinical samples which included standard identification, susceptibility testing, followed by PCR detection of staphylococcal suspected isolates and in-PCR mixed bacterial populations analysis indicated the following findings. Pure cultures analysis indicated that one of the single-locus assay had very high prevalence of false positives (Positive predictive value = 77.8%) and was excluded from further analysis. Analysis of 460 swab-derived samples indicated that the second single-locus assay misidentified 16 out of 219 MRSA's and 13 out of 90 methicillin-sensitive S. aureus's (MSSA) were misidentified as MRSA's. The double-locus detection assay misidentified 55 out of 90 MSSA's. 46 MSSA containing samples were misidentified as MRSA and 9 as other than S. aureus ending with low positive predicted value (<85%) and very low specificity (<62%). Conclusion. The results indicate that high prevalence of false-positive and false-negative reactions occurs in such assays. © 2010 Paitan et al; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Kolman, S., Arielly, H., & Paitan, Y. (2010). Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance. BMC Research Notes, 3. https://doi.org/10.1186/1756-0500-3-110

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free