Performance of a diagnostic algorithm for fibrotic hypersensitivity pneumonitis. A case–control study

4Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The differential diagnosis fibrotic hypersensitivity pneumonitis (HP) versus idiopathic pulmonary fibrosis (IPF) is important but challenging. Recent diagnostic guidelines for HP emphasize including multidisciplinary discussion (MDD) in the diagnostic process, however MDD is not comprehensively available. We aimed to establish the diagnostic accuracy and prognostic validity of a previously proposed HP diagnostic algorithm that foregoes MDD. Methods: We tested the algorithm in patients with an MDD diagnosis of fibrotic HP or IPF (case control study) and determined diagnostic test performances for diagnostic confidences of ≥ 90% and ≥ 70%. Prognostic validity was established using Cox proportional hazards models. Results: Thirty-one patients with fibrotic HP and 50 IPF patients were included. The algorithm-derived ≥ 90% confidence level for HP had high specificity (0.94, 95% confidence interval [CI] 0.83–0.99), but low sensitivity (0.35 [95%CI 0.19–0.55], J-index 0.29). Test performance was improved for the ≥ 70% confidence level (J-index 0.64) with a specificity of 0.90 (95%CI 0.78–0.97), and a sensitivity of 0.74 (95%CI 0.55–0.88). MDD fibrotic HP diagnosis was strongly associated with lower risk of death (adjusted hazard ratio [HR] 0.10 [0.01–0.92], p = 0.04), whereas the algorithm-derived ≥ 70% and ≥ 90% confidence diagnoses were not significantly associated with survival (adjusted HR 0.37 [0.07–1.80], p = 0.22, and adjusted HR 0.41 [0.05–3.25], p = 0.39, respectively). Conclusion: The algorithm-derived ≥ 70% diagnostic confidence had satisfactory test performance for MDD-HP diagnosis, with insufficient sensitivity for ≥ 90% confidence. The lowest risk of death in the MDD-derived HP diagnosis validates the reference standard and suggests that a diagnostic algorithm not including MDD, might not replace the latter.

Cite

CITATION STYLE

APA

Guler, S. A., Wohlfarth, E., Berezowska, S., Geiser, T. K., Ebner, L., & Funke-Chambour, M. (2021). Performance of a diagnostic algorithm for fibrotic hypersensitivity pneumonitis. A case–control study. Respiratory Research, 22(1). https://doi.org/10.1186/s12931-021-01727-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free