Improved sensitivity of a dual-target HIV-1 qualitative test for plasma and dried blood spots

21Citations
Citations of this article
40Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The use of nucleic acid detection for HIV type 1 (HIV-1) detection is strongly recommended in infants<18 months of age, in whom serology is unreliable. This study evaluated the Cobas AmpliPrep/Cobas TaqMan HIV-1 Qualitative Test v2.0 (TaqMan HIV-1 Qual Test, v2.0), a dual-target total nucleic acid real-time PCR assay. The limit of detection (LOD) of the new test in plasma and dried blood spots (DBS) was determined with the 2nd International HIV-1 RNAWHOstandard. The specificity of the assay was tested with EDTA plasma (n1,301) and DBS from HIV-negative adults (n1,000). The sensitivity was determined using HIV-1-positive samples (n169 adult EDTA plasma, n172 adult DBS, and n100 infant DBS) that included group M, subtypes A to H, CRF01-AE, CRF02-AG, and groups O and N. All positive specimens and a subset of the negative specimens were also tested with the Abbott RealTime HIV-1 Qual assay (RealTime). The LOD of the TaqMan assay was 20 copies/ml in plasma and 300 copies/ml in DBS, with specificities of 99.8% in plasma and 99.9% in DBS. The TaqMan assay results were 100% concordant with RealTime results in EDTA plasma samples and in 100 HIV-1-negative adult DBS. Among 172 HIV-1-positive DBS from adults, the TaqMan assay showed positive results for all DBS while RealTime missed five DBS with low target concentrations. Infant DBS results were 100% concordant. The improved sensitivity of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Qualitative Test, v2.0, compared to current commercially available assays may enable earlier diagnosis and treatment in adults and infants. The dual-target test may ensure HIV-1 detection even if a mutation is present in one of the two target regions. The DBS sample matrix facilitates virological testing in remote areas.

Cite

CITATION STYLE

APA

Templer, S. P., Seiverth, B., Baum, P., Stevens, W., Seguin-Devaux, C., & Carmona, S. (2016). Improved sensitivity of a dual-target HIV-1 qualitative test for plasma and dried blood spots. Journal of Clinical Microbiology, 54(7), 1877–1882. https://doi.org/10.1128/JCM.00128-16

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free