Real-World Effectiveness and Safety of Insulin Glargine 300 U/mL in Patients with T2D Uncontrolled on NPH or Premixed Insulins as Part of Routine Clinical Practice in Bulgaria: ToUPGRADE Study

6Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: The aim of this study is to demonstrate the real-life effectiveness and safety of insulin glargine 300 U/mL (Gla-300) in patients with type 2 diabetes (T2D) previously uncontrolled on NPH ± prandial insulin or premixed insulins in routine clinical practice in Bulgaria. Methods: This was a 24-week prospective, observational study performed in 40 inpatient and outpatient sites across the country. Results: A total of 286 patients were included in the study. The mean age (± SD) was 61.2 ± 10.0 years with duration of diabetes of 11.64 ± 7.5 years and body mass index (BMI) of 32.1 ± 5.7 kg/m2. HbA1c before Gla-300 initiation was 9.8 ± 1.0%, and fasting plasma glucose (FPG) was 13.1 ± 3.4 mmol/L. HbA1c and FPG change from baseline to week 24 was − 1.86% (p < 0.001) and − 4.8 mmol/L (p < 0.001), respectively. The proportion of patients reaching their individualized HbA1c at week 24 was 39.1% (95% CI 33.3–45.1%), while the proportion of patients reaching their individualized HbA1c target without confirmed and/or severe hypoglycaemia was 34.8% (95% CI 29.2–40.7%). At study end, 19.0% (95% CI 14.6–24.1%) achieved HbA1c < 7%. Body weight decreased from 88.3 to 87.0 kg from baseline to week 24 with mean change of − 1.3 kg (p < 0.001). The incidence and event rates of anytime confirmed (≤ 3.9 mmol/L) and/or severe hypoglycaemia were low: 7.7% and 0.42 events per patient-year, respectively. The overall Insulin Treatment Satisfaction Questionnaire (ITSQ) score increased from 53.2 to 78.2 from baseline to week 24 and the difference of 25.1 ± 21.5 points was significant (p < 0.001). Conclusions: In real-life settings, Gla-300 significantly improved glycaemic control and insulin treatment satisfaction in people with T2D who were inadequately controlled with NPH ± prandial insulin or premixed insulin analogues. Improvement of glycaemic control was associated with a very low risk of hypoglycaemia and with significant weight loss irrespective of the previous insulin regimen.

Cite

CITATION STYLE

APA

Kamenov, Z., Pehlivanova, V., Kuneva, T., Kirilov, K., Bobeva, R., Stoykova, J., & Mihalevska, S. (2021). Real-World Effectiveness and Safety of Insulin Glargine 300 U/mL in Patients with T2D Uncontrolled on NPH or Premixed Insulins as Part of Routine Clinical Practice in Bulgaria: ToUPGRADE Study. Diabetes Therapy, 12(3), 913–930. https://doi.org/10.1007/s13300-021-01022-0

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free