Improved targeting of beclomethasone diproprionate (250 μg metered dose inhaler) to the lungs of asthmatics with the Spacehaler(TM)

29Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The Spacehaler(TM) (Evans Medical Ltd, Leatherhead, U.K.) is a new, compact, inhaler device containing the same aerosol canister as a conventional metered dose inhaler (MDI). However, the design of the Spacehaler(TM) has been shown to reduce the velocity of the aerosol, thus reducing the proportion of non-respirable particles delivered to the patient. This study compared radioaerosol deposition patterns following inhalation of 250 μg of beclomethasone dipropionate from the Spacehaler(TM) and a conventional MDI (Beclazone(TM), Norton Health Care, Harlow, U.K.). After rigorous in vitro validation of the radiolabelling technique, 12 asthmatic subjects (seven men aged 20-69 years, mean baseline FEV1 2.591 (SD 0.551) received one dose of 99Tc-labelled bedomethasone diproyionate 250 μg via either a Spacehaler(TM) or MDI on each of two study days in a randomized cross-over manner. All subjects had been taught the required inhalation technique before the dose was administered. Inhalation details were recorded using a spirometer connected in series with the device. Lung and oropharyngal depositions were measured by gamma scintigraphy. The mean percentage of the metered dose deposited in the lungs was 23.0%) (SD 8.3%) for the Spacehaler(TM) and 12.8% (SD 6.8%) for the MDI (P < 0.01). However, there was no significant difference in the distribution patterns within the lungs between the two devices. Oropharyngeal deposition was significantly lower (P < 0.01) for the Spacehaler(TM) than for the MDI (mean (SD) 27.9% (16.4%) and 73.6% (8.7%), respectively] whilst the percentage of the metered dose remaining on the Spacehaler(TM) actuator was significantly greater than that on the MDI actuator (mean (SD) 48.0% (11.8%) and 12.4% (8.5%) respectively, P < 0.01]. There was evidence from the inhalation recordings that some patients experienced the 'cold Freon effect' whilst using the metered dose inhaler which may have contributed to the lower lung deposition seen with this device, This study demonstrates that the proportion of a 250 μg dose of beclomethasone diproyionate that is delivered to the lungs is significantly greater with the Spacehaler(TM) than the MDI. The Spacehaler(TM) also reduces the proportion of the does that is deposited in the oropharynx to less than half that observed with the MDI, and reduces the total dose of drug received by the patient.

Cite

CITATION STYLE

APA

Newman, S. P., Steed, K. P., Hooper, G., Jones, J. I., & Upchurch, F. C. (1999). Improved targeting of beclomethasone diproprionate (250 μg metered dose inhaler) to the lungs of asthmatics with the Spacehaler(TM). Respiratory Medicine, 93(6), 424–431. https://doi.org/10.1053/rmed.1999.0587

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free