Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents

188Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background - Despite the proven superiority of sirolimus-eluting stents (SESs) compared with bare stents in the first year after implantation, long-term outcomes of patients treated with these novel devices remain unknown. Our goal was to evaluate the clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with SESs 4 years after implantation. Methods and Results - The study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR; n=15] and fast release [FR; n=15]). Twenty-six patients underwent 4-year angiographic and IVUS follow-up and had matched assessments at all time points (index and 4-, 12-, 24-, and 48-month follow-up). One death occurred during the study period in a patient with a patent SES. There were no target-vessel revascularizations or thromboses between 2- and 4-year follow-up examinations. There was no stent thrombosis, target-lesion revascularization, death, or myocardial infarction in the SR group up to 4 years. Cumulative event-free survival rate was 87% for the total population (80% in the FR group and 93% in the SR group). In-stent late loss was slightly greater in the FR group (0.41±0.49 mm) than the SR group (0.09±0.23) after 4 years. One patient in the FR group had a 52% in-stent restenosis lesion. Percent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 4 years (FR=9.1% and SR=5.7%). Conclusions - This study confirms the longevity of the optimal outcomes observed in patients treated with sirolimus-eluting Bx Velocity stents 4 years after implantation. In-stent lumen dimensions remained essentially unchanged at 4-year follow-up, particularly in the population treated with the currently available SES (SR formulation). © 2005 American Heart Association, Inc.

Author supplied keywords

Cite

CITATION STYLE

APA

Sousa, J. E., Costa, M. A., Abizaid, A., Feres, F., Seixas, A. C., Tanajura, L. F., … Sousa, A. G. M. R. (2005). Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents. Circulation, 111(18), 2326–2329. https://doi.org/10.1161/01.CIR.0000164271.01172.1A

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free