Background: Several studies have investigated the diagnostic accuracy of tests of pericardial effusion interferon-gamma for tuberculous pericarditis in patients with pericardial effusion, but the results have varied. The aim of this study was to investigate the diagnostic accuracy of interferon-gamma for tuberculous pericarditis using meta-analysis. Methods: The PubMed and EMBASE databases were searched to identify studies investigating the diagnostic accuracy of tests for interferon-gamma in pericardial effusion for tuberculous pericarditis. The quality of eligible studies was assessed by the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2), and the sensitivities and specificities of interferon-gamma across eligible studies were pooled by a bivariate model. Results: A total of four studies encompassing 488 subjects were included. The pooled sensitivity, specificity, positive and negative likelihood ratios (NLRs) were 0.97 [95% confidence interval (CI): 0.87-0.99], 0.99 (95% CI: 0.74-1.00), 187 (95% CI: 3-12,542) and 0.03 (95% CI: 0.01-0.14), respectively. Conclusion: Testing for interferon-gamma in cases of pericardial effusion is adequate for identifying or ruling out tuberculous pericarditis.
Author supplied keywords
Cite
CITATION STYLE
Liu, C., Cui, Y. L., Ding, C. M., Wu, Y. H., Li, H. L., Liu, X. F., & Hu, Z. D. (2018). Diagnostic accuracy of interferon-gamma in pericardial effusions for tuberculous pericarditis: A meta-analysis. Journal of Thoracic Disease, 10(2), 854–860. https://doi.org/10.21037/jtd.2017.12.107