Effect of the charge process and discharge rate on the lithium stripping process visibility in LiFePO4-graphite li-ion cells during charge-discharge cycling at 0°C

3Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Commercially available 18650 LiFePO4-Graphite Li-ion cells were exposed to charge-discharge cycling at 0°C following two different charge methods: Constant current-constant voltage (CC-CV) and constant current (CC), and two different discharge rates: 1 C and 0.2 C. The effect of the charge method and discharge rate on the cell performance was analyzed. The cell exposed to CC charge and 1 C discharge-rate showed a high voltage plateau at the beginning of the discharge voltage, while a high voltage plateau was not observed in the discharge profiles of the cells exposed to a discharge rate of 0.2 C.

Cite

CITATION STYLE

APA

Mendoza-Hernandez, O. S., Hosono, E., Asakura, D., Matsuda, H., Umeda, M., & Sone, Y. (2020). Effect of the charge process and discharge rate on the lithium stripping process visibility in LiFePO4-graphite li-ion cells during charge-discharge cycling at 0°C. Electrochemistry, 88(4), 340–342. https://doi.org/10.5796/electrochemistry.20-00052