Background: 99mTc-PYP scintigraphy provides differential diagnosis of ATTR cardiomyopathy (ATTR-CM) from light chain cardiac amyloidosis and other myocardial disorders without biopsy. This study was aimed to assess the diagnostic feasibility and the operator reproducibility of 99mTc-PYP quantitative SPECT. Method: Thirty-seven consecutive patients who underwent a 99mTc-PYP thorax planar scan followed by SPECT and CT scans to diagnose suspected ATTR-CM were enrolled. For the quantitative SPECT, phantom studies were initially performed to determine the image conversion factor (ICF) and partial volume correction (PVC) factor to recover 99mTc-PYP activity concentration in the myocardium for calculating the standardized uptake value (SUV) (unit: g/ml). SUVmax was compared among groups of ATTR-CM, AL cardiac amyloidosis, and other pathogens (others) and among categories of Perugini visual scores (grades 0–3). The intra- and inter-operator reproducibility of quantitative SPECT was verified, and the corresponded repeatability coefficient (RPC) was calculated. Results: The ICF was 79,327 Bq/ml to convert count rate in pixel to 99mTc activity concentration. PVC factor as a function of the measured activity concentration ratio in the myocardium and blood-pool was [y = 1.424 × (1 − exp(− 0.759 × x)) + 0.104]. SUVmax of ATTR-CM (7.50 ± 2.68) was significantly higher than those of AL (1.96 ± 0.35) and others (2.00 ± 0.74) (all p < 0.05). SUVmax of grade 3 (8.95 ± 1.89) and grade 2 (4.71 ± 0.23) were also significantly higher than those of grade 1 (1.92 ± 0.31) and grade 0 (1.59 ± 0.39) (all p < 0.05). Correlation coefficient (R2) of SUVmax reached 0.966 to 0.978 with only small systematic difference (intra = − 0.14; inter = − 0.23) between two repeated measurements. Intra- and inter-operator RPCs were 0.688 and 0.877. Conclusions: 99mTc-PYP quantitative SPECT integrated with adjustable PVC factors is feasible to quantitatively and objectively assess the burden of cardiac amyloidosis for diagnosis of ATTR-CM.

Cite

CITATION STYLE

APA

Ren, C., Ren, J., Tian, Z., Du, Y., Hao, Z., Zhang, Z., … Huo, L. (2021). Assessment of cardiac amyloidosis with 99mTc-pyrophosphate (PYP) quantitative SPECT. EJNMMI Physics, 8(1). https://doi.org/10.1186/s40658-020-00342-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free