Due to urbanization and industrialization, which paved the door for the development of tall, multi-story structures on mountainous terrain, land is scarce in emerging nations like India. Buildings built on hilly terrain differ from those built on flat terrain due of their uneven and asymmetrical vertical and horizontal structures. These buildings are also significantly more vulnerable to earthquake pressures when located in mountainous terrain. The primary goal of the current endeavor is to investigate how structures behave on level and sloping terrain. Hillyplaces require different construction configurations than level areas. Hill structures vary from those on lowlands in that they are torsionally linked, highly irregular, and asymmetrical in boththe horizontal and vertical planes. As a result, they are vulnerable to severe damage when an earthquake strikes. The behavior of a multi-story structure with two distinct slope angles was attempted to be studied in this paper, and a comparison with flat ground was made. by taking Earthquake Zone II into account. Buildings on level ground and buildings on slanted ground are compared. The models are created with the aid of the structural analysis program ETABS. Response spectrum analysis is used for analysis. The analysis's findings, including storey shear, storey drifts, moments, and displacement, are tabulated and examined.
CITATION STYLE
Babu, K. V., Krishna, S. S. R., & Malagavelli, V. (2023). Seismic analysis of Multi storey Building on Sloping Ground and Flat Ground by using ETABS. In IOP Conference Series: Earth and Environmental Science (Vol. 1130). Institute of Physics. https://doi.org/10.1088/1755-1315/1130/1/012004