This study employs potential-monitoring techniques, cyclic voltammetry tests, alternating current (AC) voltammetry methods, and surface characterization to investigate the AC corrosion of cathodically protected X80 pipeline steel. In a non-passive neutral solution at pH 7.2, a sufficiently negative potential completely protects steel at an AC current density of 100 A/m2. In an alkaline solution at pH 9.6, more serious AC corrosion occurs at more negative cathodic protection (CP) potential, whereas without CP the steel suffers negligible corrosion. In addition, the interface capacitance increases with AC amplitude. Based on these results, the AC corrosion mechanisms that function under various conditions are analyzed and described.
CITATION STYLE
Wang, H., Du, C., Liu, Z., Wang, L., & Ding, D. (2017). Effect of alternating current on the cathodic protection and interface structure of X80 steel. Materials, 10(8). https://doi.org/10.3390/ma10080851
Mendeley helps you to discover research relevant for your work.