Correlation between dynamic contour tonometry, uncorrected and corrected Goldmann applanation tonometry, and stage of glaucoma

16Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

IMPORTANCE: Accurate determination of intraocular pressure (IOP) is crucial for the diagnosis and management of glaucoma. Objective clinical evaluation of the correction equations for Goldmann applanation tonometry (GAT) is lacking. OBJECTIVES: To investigate the difference between corrected and conventional GAT and Pascal dynamic contour tonometry (DCT) measurements, as well as the correlation between discordant IOP values and stage of glaucoma. DESIGN, SETTING, AND PARTICIPANTS: This prospective cross-sectional case series was conducted at the Department of Ophthalmology, University Hospital Zurich, and Talacker Eye Center between July 1, 2011, and May 31, 2016, among 112 white patients with glaucoma. INTERVENTIONS: Intraocular pressure measurements were performed with GAT and DCT in a randomized order. Goldmann applanation tonometry measurements were modified with 5 correction equations. MAIN OUTCOMES AND MEASURES: The primaryend point was degree of concordance between corrected or uncorrected GAT and DCT measurements. The secondary end point was association between discordant IOP measurements and the stage of glaucoma, as assessed by the Glaucoma Severity Score. RESULTS: Among the 112 patients (67 women and 45 men; mean [SD] age, 66.3 [13.1] years), 63 of the eyes in the study (56.3%) were left eyes and 85 patients (75.9%) were taking ocular antihypertensive medications. Mean (SD) IOP was 20.3 (4.5) mm Hg (95% CI, 19.4-21.1) as measured by DCT and 17.0 [4.1]mmHg (95% CI, 16.3-17.8) as measured by GAT. The mean (SD) discordance between DCT and GAT measurements was -3.3 (2.0) mmHg (95% CI, 2.9-3.6). The 5 corrected GAT values ranged from -2.7 to -5.4 mm Hg compared with DCT. The mean (SD) result of the Dresdner correction formula (17.6 [4.1] mm Hg) was closer to the DCT measurement than the original GAT measurement. The mean (SD) Glaucoma Severity Score was 4.7 (3.4) (95% CI, 4.1-5.4). The uncorrected discordance IOPDCT - IOPGAT showed a positive correlation with the Glaucoma Severity Score (rs = 0.33; P

Cite

CITATION STYLE

APA

Wachtl, J., Töteberg-Harms, M., Frimmel, S., Roos, M., & Kniestedt, C. (2017). Correlation between dynamic contour tonometry, uncorrected and corrected Goldmann applanation tonometry, and stage of glaucoma. JAMA Ophthalmology, 135(6), 601–608. https://doi.org/10.1001/jamaophthalmol.2017.1012

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free