Ethoxyquin is a chemical antioxidant used in feeds, ingredients, fats, and oils. A liquid chromatographic (LC) method for determination of ethoxyquin was developed. The method involves acetonitrile extraction of the sample and isocratic C18 reversed-phase chromatography with ammonium acetate buffer-acetonitrile as mobile phase and fluorescence detection. A collaborative study of the determination of ethoxyquin in various meals and extruded pet foods was conducted by The lams Company Research Laboratory. Eleven laboratories analyzed 16 samples (including 2 blind duplicates) consisting of 7 meat meals and 9 extruded pet foods. Sample means ranged from 0.25 to 289 ppm. Repeatability standard deviations ranged from 0.08 to 3.2 ppm, and repeatability relative standard deviations ranged from 4.5 to 32%. Reproducibility standard deviations ranged from 0.12 to 13 ppm, and reproducibility relative standard deviations ranged from 4.5 to 55%. The LC method for determination of ethoxyquin in feeds has been adopted first action by AOAC INTERNATIONAL.
CITATION STYLE
Schreier, C. J., & Greene, R. J. (1997). Determination of Ethoxyquin in Feeds by Liquid Chromatography: Collaborative Study. Journal of AOAC International, 80(4), 725–731. https://doi.org/10.1093/jaoac/80.4.725