Measuring and maintaining organ perfusion in a patient with Takayasu's arteritis undergoing cardiac surgery*

1Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Takayasu's arteritis is a rare vasculitis affecting the aorta and its branches. Disease progression can result in arterial stenosis and subsequent organ dysfunction. Estimating organ perfusion by measuring the peripheral blood pressure can be challenging because it may be altered by arterial stenosis. We report the case of a 61-year-old woman with Takayasu's arteritis with aortic and mitral regurgitation who presented for aortic valve replacement and mitral valvuloplasty. Peripheral arterial pressure was considered a less reliable surrogate for organ perfusion because the patient had diminished blood flow in both the lower and upper extremities. In addition to the bilateral radial arterial pressure, the blood pressure in the ascending aorta was monitored to estimate the patient's organ perfusion pressure during cardiopulmonary bypass. The initial target blood pressure was determined based on the pre-operative baseline and modified by measurement of the aortic pressure. Cerebral oximetry using near-infrared spectroscopy and mixed venous saturation was monitored to estimate oxygen supply-demand balance, which helped evaluate cerebral perfusion and determine the transfusion threshold. The entire procedure was uneventful, and no organ dysfunction was observed postoperatively.

Cite

CITATION STYLE

APA

Dan, K., Takahashi, K., & Lefor, A. K. (2023). Measuring and maintaining organ perfusion in a patient with Takayasu’s arteritis undergoing cardiac surgery*. Anaesthesia Reports, 11(2). https://doi.org/10.1002/anr3.12236

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free