Evaluation of contrast Sonazoid-enhanced ultrasonography for the detection of hepatic metastases in breast cancer

25Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

Abstract

Background: The present study was aimed to evaluate the usefulness of contrast Sonazoid-enhanced ultrasonography (US) for the detection of hepatic metastases in breast cancer patients and compare the clinical efficacy and sensitivity of this technique with conventional contrast unenhanced B-mode US in follow-up examinations of breast cancer patients with liver metastasis. Methods: We assessed a total of 84 hepatic tumors from 24 patients diagnosed with or suspected of having metastatic cancer. These hepatic nodules were diagnosed through imaging, including dynamic magnetic resonance imaging (MRI), contrast-enhanced computed tomography (CECT) scan, B-mode US or contrast Sonazoid-enhanced US (SEUS). Differences in the sensitivity between US and SEUS were compared using MR imaging, CECT, and follow-up imaging. Results: A total of 79 nodules were diagnosed as metastatic tumors. The remaining nodules were diagnosed as benign tumors (hepatic hemangioma: n = 3; local fatty change: n = 2). SEUS precisely detected the presence or absence of hepatic tumors in the 24 patients examined, showing a sensitivity of 98.8 % (83 of 84 lesions) for total imaged solid liver lesions, with an accuracy of 98.7 % (78 of 79 lesions) for total metastatic breast cancer lesions. In contrast, conventional B-mode US imaging revealed hepatic tumor lesions at a sensitivity of 66.7 % (56 of 84 lesions) and an accuracy of 64.6 % (51 of 79 lesions), respectively. Furthermore, the false positive and false negative rates were, respectively, 6.33 and 29.1 % for B-mode US and 0 and 1.3 % for SEUS. Moreover, twenty-seven metastatic tumors and five benign lesions (3 hemangiomas and 2 focal fatty changes/sparings) were imaged using SEUS but not conventional B-mode US. Significant differences in diagnostic accuracy rates between contrast Sonazoid-enhanced US and conventional B-mode US were observed (Wilcoxon signed rank test: p = 0.0009). No severe adverse events occurred during SEUS after the administration of Sonazoid, except for a grade 1 skin reaction and nausea in one patient. Conclusion: These results suggested that Sonazoid could be safely administrated to breast cancer patients with liver metastatic disease. Thus, contrast Sonazoid-enhanced US is a feasible and more effective method than B-mode US for the detection of hepatic metastasis, particularly for small metastatic breast cancer lesions less than 14 mm in diameter, showing significant high sensitivity and accuracy.

Cite

CITATION STYLE

APA

Mishima, M., Toh, U., Iwakuma, N., Takenaka, M., Furukawa, M., & Akagi, Y. (2016). Evaluation of contrast Sonazoid-enhanced ultrasonography for the detection of hepatic metastases in breast cancer. Breast Cancer, 23(2), 231–241. https://doi.org/10.1007/s12282-014-0560-0

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free