Objective-To assess the frequency of early remodelling of coronary stenosis morphology after thrombolytic treatment in patients with acute myocardial infarction. Design-Coronary angiograms were analysed by a computerised edge detection analysis system. Coronary stenosis severity was measured and morphology classified as smooth or complex. Patients-Coronary arteriograms were obtained approximately 90 min and 24 h after thrombolytic treatment from 40 patients with acute myocardial infarction. Main results-Stenosis morphology was complex in 22 patients (65%) and smooth in 11 (32%) 90 min after thrombolysis. The morphology of 11 (50%) complex coronary stenoses and three (27%) smooth stenoses had changed at 24 h (P < 0·05). The transition from complex to smooth was associated with a reduction in stenosis severity from 65 (4)% to 51 (5)% (P < 0·05). The stenosis severity was 63 (4)% and 60 (5)% in those with persistently complex morphology, and 56 (7)% and 50 (5)% in those with persistently smooth morphology at 90 min and 24 h respectively (NS). Conclusions-Transition of morphology from complex to smooth within 24 h is common. This transition is associated with a reduction in stenosis severity of a degree greater than that found in persistently smooth stenoses over the same interval. 50% of stenoses are smooth at 24 h.
Mendeley helps you to discover research relevant for your work.
CITATION STYLE
Tousoulis, D., Andreotti, F., Hackett, D., Haider, A. W., Maseri, A., & Davies, G. (1995). Early remodelling of coronary stenoses after thrombolytic treatment in patients with acute myocardial infarction. Heart, 74(3), 229–234. https://doi.org/10.1136/hrt.74.3.229