1.5 kW isolated bi-directional DC-DC converter with a flyback snubber

17Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.
Get full text

Abstract

An isolated bi-directional full-bridge DC-DC converter with high conversion ratio, high output power and soft start-up capability for battery charging/discharging is proposed in this paper. The use of a capacitor and a flyback converter can clamp the voltage spike caused by the current difference between the current-fed inductor and leakage inductance of the isolation transformer, and can reduce the current flowing through the active switches at the current-fed side. Operational principle of the proposed converter is first described, and the design equation is then derived. A 1.5 kW prototype with low-side voltage of 48V and high-side voltage of 360V has been implemented, from which experimental results have verified its feasibility.

Cite

CITATION STYLE

APA

Wu, T. F., Chen, Y. C., Yang, J. G., Huang, Y. C., Shyu, S. S., & Lee, C. L. (2009). 1.5 kW isolated bi-directional DC-DC converter with a flyback snubber. In Proceedings of the International Conference on Power Electronics and Drive Systems (pp. 164–169). https://doi.org/10.1109/PEDS.2009.5385736

Register to see more suggestions