Abstract
Objectives . This study evaluated the influence of cavity surface finishing with diamond burs of different grit mounted on high-speed turbine and ultrasound on the roughness and microshear bond strength (MBS) of a lithium silicate glass-ceramic to enamel and dentin. Methods . Enamel and dentin specimens were divided into seven groups, according to the type of surface finishing: 1200-grit sandpaper (control), two different brands of medium-grit and fine-grit diamond burs in a high-speed turbine; medium-grit and fine-grit CVD (chemical vapor deposition) tips in an ultrasonic device. Roughness parameters ( n = 5 ) and MSBS to a glass-ceramic ( n = 10 ) were determined. Data were analyzed using ANOVA and Tukey’s test ( α = 5%). Results . Control group showed lower mean roughness readings and groups that used medium-grit diamond burs showed the highest mean roughness values. Regarding MSBS, there was no statistical difference when comparing the groups gritted with the same brand of medium- and fine-grit burs and tips. Conclusions . Cavity surface finishing influenced the roughness parameters and MSBS of a glass-ceramic to enamel and dentin. Medium-grit diamond burs in high-speed turbine showed the highest mean roughness values. Fine-grit CVD tips in ultrasound presented the highest MSBS values for both enamel and dentin.
Cite
CITATION STYLE
Gonzaga, C. C., Bravo, R. P., Pavelski, T. V., Garcia, P. P., Correr, G. M., Leonardi, D. P., … Furuse, A. Y. (2015). Enamel and Dentin Surface Finishing Influence on the Roughness and Microshear Bond Strength of a Lithium Silicate Glass-Ceramic for Laminate Veneers. International Scholarly Research Notices, 2015, 1–7. https://doi.org/10.1155/2015/243615
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.