Comparison of sequentially measured Aloka echo-tracking one-point pulse wave velocity with SphygmoCor carotid–femoral pulse wave velocity

  • Vriz O
  • Driussi C
  • La Carrubba S
  • et al.
N/ACitations
Citations of this article
28Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: Recently, echo-tracking-derived measures of arterial stiffness have been introduced in clinical practice for the assessment of one-point pulse wave velocity. The purpose of this study was to find a relation between carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity, and to find a value of one-point carotid pulse wave velocity that predicts carotid-femoral pulse wave velocity higher than 12 m/s.METHODS: A total of 160 consecutive subjects (112 male/48 female, mean age = 51.5 ± 14.1 years; 96 healthy, 44 hypertensives, 13 with aortic valve disease, and 7 with left ventricular dysfunction) were studied. Carotid-femoral pulse wave velocity was measured with the SphygmoCor system and one-point carotid pulse wave velocity with high-definition echo-tracking system (ProSound Alpha10; Aloka, Tokyo, Japan).RESULTS: Both carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity correlated significantly with each other (r = 0.539, p < 0.001) and with age (one-point carotid pulse wave velocity r = 0.618, carotid-femoral pulse wave velocity r = 0.617, p < 0.0001 for both). Median value of carotid-femoral pulse wave velocity (7.2 m/s, 95% confidence interval = 6.2-8.9) was systematically higher than that of one-point carotid pulse wave velocity (5.8 m/s, 95% confidence interval = 5-6.6). The area under the receiver operating characteristic curve was 0.85, identifying the cutoff for one-point pulse wave velocity of 6.65 m/s as the best predictor of carotid-femoral pulse wave velocity more than 12 m/s (sensitivity = 0.818, specificity = 0.819).CONCLUSIONS: One-point carotid pulse wave velocity correlates with carotid-femoral pulse wave velocity, and the cutoff of 6.65 m/s was the best predictor of carotid-femoral pulse wave velocity over 12 m/s.

Cite

CITATION STYLE

APA

Vriz, O., Driussi, C., La Carrubba, S., Di Bello, V., Zito, C., Carerj, S., & Antonini-Canterin, F. (2013). Comparison of sequentially measured Aloka echo-tracking one-point pulse wave velocity with SphygmoCor carotid–femoral pulse wave velocity. SAGE Open Medicine, 1. https://doi.org/10.1177/2050312113507563

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free