Effect of temperature variation and pre-sustained loading on the bond between basalt FRP sheets and concrete

3Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

The coupled effects of temperature variation and pre-sustained loading on the bond between basalt fiber reinforced polymer (BFRP) sheets and a concrete substrate were studied. Single lap-shear test specimens were exposed to temperatures of 15, 30, 40, 50, and 60 °C for 3 h with pre-sustained loading at 35% of the ultimate load capacity (Fu). Compared with the case of 15 °C, the interfacial fracture energy of the specimens at 30 and 40 °C increased by 46% and 11%, respectively, whereas those reduced by 73% and 77% at 50 and 60 °C, respectively. The coupled effects of temperature and pre-sustained loading on the effective bond length are insignificant for the specimens at both 15 and 30 °C and the effective bond length increased to 300 mm when the temperature exceeded 40 °C. The failure crack still occurred in the concrete substrate at the temperatures of 15 and 30 °C, and changed to the debonding of the adhesive layer from the concrete substrate at the temperature above 30 °C.

Cite

CITATION STYLE

APA

He, J., Lu, Z., Tan, S., Ueda, T., Pan, Y., Xie, J., & Xian, G. (2020). Effect of temperature variation and pre-sustained loading on the bond between basalt FRP sheets and concrete. Materials, 13(7). https://doi.org/10.3390/ma13071530