Diagnostic performance of a stand-alone central blood pressure monitor: Application of central blood pressure in the diagnosis of high blood pressure

21Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUNDOscillometric central blood pressure (CBP) monitors have emerged as a new technology for blood pressure (BP) measurements. With a newly proposed diagnostic threshold for CBP, we investigated the diagnostic performance of a novel CBP monitor.METHODSWe recruited a consecutive series of 138 subjects (aged 30-93 years) without previous use of antihypertensive agents for simultaneous invasive and noninvasive measurements of BP in a catheterization laboratory. With the cutoff (CBP ≥130/90mm Hg) for high blood pressure (HBP), the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the novel CBP monitor were calculated with reference to the measured CBP. In comparison, the diagnostic performance of the conventional cuff BP was also evaluated.RESULTSThe noninvasive CBP for detecting HBP in a sample with a prevalence of 52% showed a sensitivity of 93% (95% confidence interval (CI) = 91-95), specificity of 95% (95% CI = 94-97), PPV of 96% (95% CI = 94-97), and NPV of 93% (95% CI = 90-95). In contrast, with cuff BP and the traditional HBP criterion (cuff BP ≥140/90mm Hg), the sensitivity, specificity, PPV, and NPV were 49% (95% CI = 44-53), 94% (95% CI = 92-96), 90% (95% CI = 86-93), and 63% (95% CI 59-66), respectively.CONCLUSIONSA stand-alone oscillometric CBP monitor may provide CBP values with acceptable diagnostic accuracy. However, with reference to invasively measured CBP, cuff BP had low sensitivity and NPV, which could render possible management inaccessible to a considerable proportion of HBP patients, who may be identifiable through noninvasive CBP measurements from the CBP monitor. © 2014 American Journal of Hypertension, Ltd.

Cite

CITATION STYLE

APA

Cheng, H. M., Sung, S. H., Chuang, S. Y., Pearson, A., Tufanaru, C., White, S., … Chen, C. H. (2014). Diagnostic performance of a stand-alone central blood pressure monitor: Application of central blood pressure in the diagnosis of high blood pressure. American Journal of Hypertension, 27(3), 382–391. https://doi.org/10.1093/ajh/hpt282

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free