Predicting ambulatory energy expenditure in lower limb amputees using multi-sensor methods

13Citations
Citations of this article
120Readers
Mendeley users who have this article in their library.

Abstract

Purpose To assess the validity of a derived algorithm, combining tri-axial accelerometry and heart rate (HR) data, compared to a research-grade multi-sensor physical activity device, for the estimation of ambulatory physical activity energy expenditure (PAEE) in individuals with traumatic lower-limb amputation. Methods Twenty-eight participants [unilateral (n = 9), bilateral (n = 10) with lower-limb amputations, and non-injured controls (n = 9)] completed eight activities; rest, ambulating at 5 progressive treadmill velocities (0.48, 0.67, 0.89, 1.12, 1.34m.s-1) and 2 gradients (3 and 5%) at 0.89m. s-1. During each task, expired gases were collected for the determination of VO _2 and subsequent calculation of PAEE. An Actigraph GT3X+ accelerometer was worn on the hip of the shortest residual limb and, a HR monitor and an Actiheart (AHR) device were worn on the chest. Multiple linear regressions were employed to derive population-specific PAEE estimated algorithms using Actigraph GT3X+ outputs and HR signals (GT3X+HR). Mean bias ±95% Limits of Agreement (LoA) and error statistics were calculated between criterion PAEE (indirect calorimetry) and PAEE predicted using GT3X+HR and AHR. Results Both measurement approaches used to predict PAEE were significantly related (P<0.01) with criterion PAEE. GT3X+HR revealed the strongest association, smallest LoA and least error. Predicted PAEE (GT3X+HR; unilateral; r = 0.92, bilateral; r = 0.93, and control; r = 0.91, and AHR; unilateral; r = 0.86, bilateral; r = 0.81, and control; r = 0.67). Mean±SD percent error across all activities were 18±14%, 15±12% and 15±14% for the GT3X+HR and 45 ±20%, 39±23% and 34±28% in the AHR model, for unilateral, bilateral and control groups, respectively. Conclusions Statistically derived algorithms (GT3X+HR) provide a more valid estimate of PAEE in individuals with traumatic lower-limb amputation, compared to a proprietary group calibration algorithm (AHR). Outputs from AHR displayed considerable random error when tested in a laboratory setting in individuals with lower-limb amputation.

Cite

CITATION STYLE

APA

Ladlow, P., Nightingale, T. E., Polly McGuigan, M., Bennett, A. N., Phillip, R. D., & Bilzon, J. L. J. (2019). Predicting ambulatory energy expenditure in lower limb amputees using multi-sensor methods. PLoS ONE, 14(1). https://doi.org/10.1371/journal.pone.0209249

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free