Abstract
Helium gas at room temperature is known to diffuse through the epoxies commonly used in various low temperature applications, which can complicate leak detection. The helium flux typically decreases with decreasing temperature. We have measured the flux of helium that passes though thin sections of as-cast clear Stycast 1266, Stycast 2850FT (black) and TRA-BOND 2151 (blue) epoxies as a function of temperature in the range 130K < T < 300K. We analyze the data to create normalized (to constant sample thickness and pressure differential) data for comparison. We report the preliminary temperature-dependent fluxes we have measured, which show significant differences among the epoxies studied. © Published under licence by IOP Publishing Ltd.
Cite
CITATION STYLE
Lovinger, D. J., & Hallock, R. B. (2012). Temperature dependence of helium diffusion through common epoxies. In Journal of Physics: Conference Series (Vol. 400). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/400/5/052006