Abstract

Classically, ultrasonic arrays achieved physical beam-forming through the application of phase delays to the parallel transmission of elements. Alternatively, beam-forming may be emulated through post-processing of sequentially transmitted array data. Though exactly equivalent for linear systems, these parallel and sequential fields differ in their nonlinear propagation. Information pertaining to elastic nonlinearity is encoded onto the relative parallel/sequential field by interference between the field components of individual element transmissions. A family of nonlinear imaging techniques has been developed which exploit differences between parallel and sequential fields in order to image elastic nonlinearity. Diffuse energy and coherent scattering variants of the technique are demonstrated for the imaging and characterization of contact-acoustic nonlinearity in application to the detection and sizing of closed fatigue cracks.

Cite

CITATION STYLE

APA

Potter, J. N., Chen, J., Croxford, A. J., & Drinkwater, B. W. (2016). Ultrasonic phased array imaging of contact-acoustic nonlinearity. In Proceedings of Meetings on Acoustics (Vol. 29). Acoustical Society of America. https://doi.org/10.1121/2.0000409