Surgery-related characteristics, efficacy, safety and surgical team satisfaction of three-dimensional heads-up system versus traditional microscopic equipment for various vitreoretinal diseases

13Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare the three-dimensional (3D) heads-up surgery with the traditional microscopic (TM) surgery for various vitreoretinal diseases. Methods: A medical record review of patients that underwent 3D heads-up or TM vitreoretinal surgeries was performed from May 2020 to October 2021 in this retrospective case–control study. Main outcome measures included surgery-related characteristics, efficacy, safety, and satisfaction feedback from the surgical team. Results: A total of 220 (47.6%) and 242 (52.4%) eyes were included in the 3D and TM groups, respectively. The 3D heads-up system significantly benefits delicate surgical steps, like the epiretinal membrane (ERM) peeling for ERM and internal limiting membrane peeling for idiopathic macular holes (P < 0.05). The 3D heads-up system could facilitate a significantly better visual outcome for pathologic myopic foveoschisis (P = 0.049), while no difference by TM surgery (P = 0.45). For the satisfaction feedback, the 3D heads-up system was rated significantly higher in most subscales and the overall score (P < 0.05). The surgeons’ ratings on operating accuracy and the first assistants’ rating on operating accuracy and operation cooperation were significantly higher in the TM group than in the 3D group (P < 0.05). Besides that, the 3D heads-up surgery was comparable with TM surgery in the surgery-related characteristics, choice of tamponades, postoperative VA, primary anatomic success, and perioperative complications (P > 0.05). Conclusion: The efficacy and safety of the 3D heads-up surgery were generally comparable to the TM surgery. The 3D heads-up system could significantly benefit delicate surgical steps and achieve better surgical team satisfaction.

Cite

CITATION STYLE

APA

Zhao, X. yu, Zhao, Q., Li, N. ning, Meng, L. hui, Zhang, W. fei, Wang, E. qian, & Chen, Y. xin. (2023). Surgery-related characteristics, efficacy, safety and surgical team satisfaction of three-dimensional heads-up system versus traditional microscopic equipment for various vitreoretinal diseases. Graefe’s Archive for Clinical and Experimental Ophthalmology, 261(3), 669–679. https://doi.org/10.1007/s00417-022-05850-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free