Estimation of measurement error in plasma HIV-1 RNA assays near their limit of quantification

11Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

Background Plasma HIV-1 RNA levels (pVLs), routinely used for clinical management, are influenced by measurement error (ME) due to physiologic and assay variation. Objective To assess the ME of the COBAS HIV-1 Ampliprep AMPLICOR MONITOR ultrasensitive assay version 1.5 and the COBAS Ampliprep Taqman HIV-1 assay versions 1.0 and 2.0 close to their lower limit of detection. Secondly to examine whether there was any evidence that pVL measurements closest to the lower limit of quantification, where clinical decisions are made, were susceptible to a higher degree of random noise than the remaining range. Methods We analysed longitudinal pVL of treatment-naïve patients from British Columbia, Canada, during their first six months on treatment, for time periods when each assay was uniquely available: Period 1 (Amplicor): 08/03/2000-01/02/2008; Period 2 (Taqman v1.0): 07/01/ 2010-07/03/2012; Period 3 (Taqman v2.0): 08/03/2012-30/06/2014. ME was estimated via generalized additive mixed effects models, adjusting for several clinical and demographic variables and follow-up time. Results The ME associated with each assay was approximately 0.5 log10 copies/mL. The number of pVL measurements, at a given pVL value, was not randomly distributed; values < 250 copies/ mL were strongly systematically overrepresented in all assays, with the prevalence decreasing monotonically as the pVL increased. Model residuals for pVL <250 copies/mL were approximately three times higher than that for the higher range, and pVL measurements in this range could not be modelled effectively due to considerable random noise of the data. Conclusions Although the ME was stable across assays, there is substantial increase in random noise in measuring pVL close to the lower level of detection. These findings have important clinical significance, especially in the range where key clinical decisions are made. Thus, pVL values < 250 copies/mL should not be taken as the truth and repeat pVL measurement is encouraged to confirm viral suppression.

Cite

CITATION STYLE

APA

Lima, V. D., Wang, L., Brumme, C., Wu, L., Montaner, J. S. G., & Harrigan, P. R. (2017). Estimation of measurement error in plasma HIV-1 RNA assays near their limit of quantification. PLoS ONE, 12(2). https://doi.org/10.1371/journal.pone.0171155

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free