Diagnostic accuracy of ultrasound for detecting large-vessel giant cell arteritis using FDG PET/CT as the reference

50Citations
Citations of this article
58Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: The diagnostic accuracy of axillary artery US in the diagnosis of large-vessel (LV)-GCA using 18F-fluorodeoxyglucose (FDG) PET/CT as reference standard was prospectively evaluated in GCA-suspected patients. As an exploratory analysis, the diagnostic accuracy of cranial artery FDG PET/CT was evaluated. Methods: Briefly, the inclusion criteria were age ≥50 years, raised inflammatory markers and potential GCA symptoms. Patients in immunosuppressive therapy or with a previous diagnosis of GCA or PMR were excluded. Examinations were performed pre-treatment. LV-GCA reference diagnosis was a clinical diagnosis of GCA and PET-proven LV inflammation. GCA patients fulfilling ACR criteria were considered as cranial-GCA (c-GCA). Patients without GCA were considered controls. Receiver operating characteristic curve analysis of the US-measured axillary intima-media thickness was performed. FDG uptake in temporal, maxillary and vertebral arteries was also assessed. Results: Forty-six patients were diagnosed with LV-GCA, 10 with isolated c-GCA, and in 34 patients GCA was dismissed. Axillary US yielded a sensitivity of 76% and a specificity of 100% for LV-GCA. An axillary intima-media thickness cut-off of 1.0 mm yielded a sensitivity of 74% and a specificity of 92%. Adding LV US to temporal assessment increased sensitivity from 71% to 97% (all GCA patients). Cranial artery PET showed a diagnostic sensitivity of 78% and specificity of 100% for c-GCA. Conclusion: Axillary artery US shows high accuracy for the LV-GCA diagnosis. Building upon the recent EULAR recommendations, we propose a diagnostic algorithm with US as the first-line confirmatory test, not only in c-GCA-suspected patients, but in all patients suspected of GCA.

Cite

CITATION STYLE

APA

Nielsen, B. D., Hansen, I. T., Keller, K. K., Therkildsen, P., Gormsen, L. C., & Hauge, E. M. (2020). Diagnostic accuracy of ultrasound for detecting large-vessel giant cell arteritis using FDG PET/CT as the reference. Rheumatology (United Kingdom), 59(8), 2062–2073. https://doi.org/10.1093/rheumatology/kez568

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free