Percutaneous nephrostomy: Comparison of sonographic and fluoroscopic guidance

65Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Both sonography and fluoroscopy have been recommended for renal localization and needle guidance for percutaneous nephrostomy. The respective efficacies of both methods have been compared in a prospective study of 88 patients undergoing percutaneous nephrostomy by the catheter over guide wire technique. Fifty-five patients had initial puncture using either an A-mode (42 patients) or real time (13 patients) sonographic aspiration transducer, while 33 patients had single plane vertical beam fluoroscopy for puncture guidance. The use of either sonographic method for the initial needle puncture significantly reduced the number of puncture attempts (p = 0.000004) and potential iatrogenic risk, eliminated the need for intravenous administration of contrast material, allowed initial safe introduction of a larger caliber needle, and decreased the length of time needed to perform the procedure.

Cite

CITATION STYLE

APA

Zegel, H. G., Pollack, H. M., Banner, M. P., Goldberg, B. B., Arger, P. H., Mulhern, C., … Koolpe, H. (1981). Percutaneous nephrostomy: Comparison of sonographic and fluoroscopic guidance. American Journal of Roentgenology, 137(5), 925–927. https://doi.org/10.2214/ajr.137.5.925