The aim of this study was to systematically search literature and conduct a meta-analysis comparing the clinical efficacy and safety of Evolut R and Sapien 3 valves for transcatheter aortic valve implantation (TAVI). The PubMed, Biomed Central, Scopus, Cochrane library and Google scholar databases were searched for articles published up to June, 2019. A total of 5 studies were included. In total, 795 patients underwent TAVI with Evolut R, while 665 patients received the Sapien 3 valve in the included studies. Overall device success with Evolut R was 95.7% and with Sapien 3 was 94.2%. Pooled data indicated no significant differences between the 2 valves (OR, 1.12; 95% CI, 0.66-1.89; P=0.68; I2 =0%). No significant differences were observed in the incidence of none to mild paravalvular leakage between the 2 groups (OR, 1.71; 95% CI, 0.83-3.54; P=0.14; I 2 =0%). Both mean [random; mean difference (MD) = -3.96; 95% CI, -4.61 to -3.31; P<0.00001, I2 =0%] and peak (random; MD = -6.85; 95% CI, -8.22 to -5.48; P<0.00001, I2 =0%) aortic valve gradients were significantly lower with Evolut R. No significant differences were observed in the 30-day mortality (OR, 1.32; 95% CI, 0.45-3.87; P=0.62; I2 =0%) or 30-day stroke outcomes (OR, 0.76; 95% CI, 0.32-1.81; P=0.54; I2 =0%) between the 2 devices. On the whole, the findings of this study indicate that Evolut R and Sapien 3 valves may be comparable in terms of device success and short-term complications. The differences between the 2 devices for post-operative moderate to severe paravalvular leak and permanent pacemaker implantation remain unclear. There is thus a need for a large multi-center randomized controlled trial to provide stronger evidence on this subject.

Cite

CITATION STYLE

APA

He, C., Xiao, L., & Liu, J. (2019). Safety and efficacy of self‑expandable Evolut R vs. balloon‑expandable Sapien 3 valves for transcatheter aortic valve implantation: A systematic review and meta‑analysis. Experimental and Therapeutic Medicine. https://doi.org/10.3892/etm.2019.8000

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free