Abstract
Two metal-organic frameworks, DUT-4(Al) and MIL-100(Fe), were explored as sensitive layers deposited at the surface of QCM transducers for the detection of α-pinene, a terpenic volatile organic compound encountered in indoor air at a trace level. Both sensors displayed sensitive, fast, reversible and repeatable response toward exposure to α-pinene, in complementary ranges of contaminant concentration: DUT-4(Al)@QCM was demonstrated to be attractive for the detection of α-pinene at 0.5 ppm < Cα-pinene < 4.8 ppm, while MIL-100(Fe)@QCM was found more efficient at Cα-pinene > 4.8 ppm. As an alternative to using two complementary QCM sensors, a single device prepared by coating the QCM by mixing DUT-4(Al) and MIL-100(Fe) was envisaged. Interestingly, DUT-4(Al)/MIL-100(Fe)@QCM benefited from a synergistic effect of both MOFs: it showed high sensitivity for detecting α-pinene in a wider range of concentration than that explored with sensors based on a single MOF, without losing the high level of sensor performances, in terms of response time, reversibility and repeatability.
Cite
CITATION STYLE
Conti, P. P., Iacomi, P., Brântuas, P. F., Nicolas, M., Anton, R., Moularat, S., … Devautour-Vinot, S. (2024). MOF-based sensors for the detection of airborne α-pinene. RSC Applied Interfaces, 1(6), 1166–1173. https://doi.org/10.1039/d4lf00027g