Incidence, risk factors, and clinical sequelae of angiographic peri-stent contrast staining after sirolimus-eluting stent implantation

98Citations
Citations of this article
70Readers
Mendeley users who have this article in their library.

Abstract

Background-: We have noted abnormal angiographic findings-at the sites of drug-eluting stent implantation, suggesting contrast staining outside the stent struts-that do not fulfill the classic definition of coronary artery aneurysm. We propose a new term, peri-stent contrast staining (PSS), for these abnormal angiographic findings and assess their incidence, risk factors, and clinical sequelae. Methods and results-: Peri-stent contrast staining was defined as contrast staining outside the stent contour extending to 20% of the stent diameter. The study population consisted of 3081 lesions (1998 patients) that were treated exclusively with sirolimus-eluting stents and were evaluated by follow-up angiography within 12 months after sirolimus-eluting stent implantation in a single center. Late acquired PSS was observed in 58 lesions (1.9%) in 49 patients (2.5%). Independent risk factors of PSS included chronic total occlusion, whereas negative risk factors for PSS were left circumflex coronary artery lesion and in-stent restenosis lesion. Stent fracture was more frequently observed in lesions with PSS than in lesions without PSS (43.1% versus 5.4%, P<0.0001). Excluding 269 lesions with target-lesion revascularization within 12 months, the study population for long-term follow-up consisted of 51 lesions (42 patients) with PSS and 2761 lesions (1751 patients) without PSS. Cumulative incidence of target-lesion revascularization and definite very late stent thrombosis at 3 years in the PSS group was higher than that in the non-PSS group (15.0% versus 6.5%, and 8.2% versus 0.2%, respectively). Conclusions-: Peri-stent contrast staining found within 12 months after sirolimus-eluting stent implantation appeared to be associated with subsequent target-lesion revascularization and very late stent thrombosis. © 2011 American Heart Association, Inc.

Cite

CITATION STYLE

APA

Imai, M., Kadota, K., Goto, T., Fujii, S., Yamamoto, H., Fuku, Y., … Mitsudo, K. (2011). Incidence, risk factors, and clinical sequelae of angiographic peri-stent contrast staining after sirolimus-eluting stent implantation. Circulation, 123(21), 2382–2391. https://doi.org/10.1161/CIRCULATIONAHA.110.003459

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free