Summary: Standardized single-injection 3-station moving-table 3T contrast-enhanced MR angiography (CE-MRA) is reliable for stenosis detection and classification in peripheral arterial occlusive disease with equivalent diagnostic performance as 1.5T CE-MRA, while contrast-tonoise ratio significantly increased at 3T for identical contrast dosage. Background: Contrast-enhanced MR angiography (CE-MRA) has evolved into a reliable imaging technique for peripheral arterial occlusive disease (PAOD). Recent advances in MRI technology offer large homogeneous magnetic fields with comparable Field-of-Views at 3T and 1.5T, allowing visualization of the complete runoff vascular tree by single-injection 3-station (pelvic/thigh/calf) moving-table CE-MRA. Diagnostic performance of 3T versus 1.5T CE-MRA has not yet been described. The purpose of this study was to compare diagnostic accuracy of 3T CE-MRA in POAD in an equivalence trial with 1.5T CE-MRA, with conventional digital subtraction angiography (DSA) as the standard of reference. Methods: In nineteen patients (13 men; mean age 69 years), DSA and standardized single-injection 3-station moving-table CE-MRA with equivalent acquisition protocols and contrast dosage were performed at 3T and 1.5T MRI (Philips, Best, the Netherlands). For CE-MRA, 0.2 mmol/kg body weight gadoterate meglumine was injected, with the first half of the bolus at 2 mL/s and second half at 0.6 mL/s. At 1.5T, a quadrature body coil (QBC) was used for imaging pelvic and thigh stations and a 4-element phased array coil for calf station. At 3T, a QBC was used in all three stations. DSA was performed using iomeprol injection at variable volumes and flow rates depending on the arterial segment. The arterial tree in each patient was divided into 27 segments, infrarenal aorta, common and external iliac arteries, common and superficial femoral arteries, popliteal arteries in thigh and calf station, tibiofibular trunk, proximal and distal halves of the anterior and posterior tibial arteries and peroneal arteries. Visual stenosis classification was performed in consensus by two radiologists in blinded manner using the following categories: class 1 (0%-stenosis), 2 (1-50%), 3 (51-75%), 4 (76-99%) and 5 (100%). Quantitative analysis of contrast-to-noise ratio (CNR) was performed for the external iliac artery and the superficial femoral artery. Results: Figure 1 shows an example for 1.5T (A) and 3T CE-MRA (B) and DSA (C). 500 arterial segments (97.5% of all available) were evaluated. 105 segments (21%) were appointed with a relevant stenosis (≥class 2) on (Figure presented) DSA. 3T and 1.5T CE-MRA showed equivalent excellent agreement with DSA regarding stenosis classification (table 1). 3T CE-MRA achieved 3.4 ±1.4 times higher (mean values 96±31 versus 30±10, p<0.001) CNR for the superficial femoral artery and 3.0±1.4 times higher (mean values 58 ±17 versus 21±5, p<0.001) for the external iliac artery. Conclusions: Standardized single-injection 3-station moving-table 3T CEMRA is reliable for stenosis detection and classification in POAD with equivalent diagnostic performance as 1.5T CE-MRA, while CNR significantly increased at 3T for identical contrast dosage.
CITATION STYLE
van den Bosch, H., Westenberg, J. J., Duijm, L. E., Daniels-Gooszen, A., Kersten, E., Cuypers, P. W., & de Roos, A. (2012). 3T versus 1.5T MR angiography in peripheral arterial occlusive disease: an equivalence trial in comparison with digital subtraction angiography. Journal of Cardiovascular Magnetic Resonance, 14(S1). https://doi.org/10.1186/1532-429x-14-s1-p139
Mendeley helps you to discover research relevant for your work.