The results are presented using the procedure outlined by the Standardisation Project for Optical Techniques of Strain measurement to calibrate a digital image correlation system. The process involves comparing the experimental data obtained with the optical measurement system to the theoretical values for a specially designed specimen. The standard states the criteria which must be met in order to achieve successful calibration, in addition to quantifying the measurement uncertainty in the system. The system was evaluated at three different displacement load levels, generating strain ranges from 289 μstrain to 2110 μstrain. At the 289 μstrain range, the calibration uncertainty was found to be 14.1 μstrain, and at the 2110 μstrain range it was found to be 28.9 μstrain. This calibration procedure was performed without painting a speckle pattern on the surface of the metal. Instead, the specimen surface was prepared using different grades of grit paper to produce the desired texture.

Cite

CITATION STYLE

APA

Sebastian, C., & Patterson, E. (2010). SPOTS calibration example. In EPJ Web of Conferences (Vol. 6). EDP Sciences. https://doi.org/10.1051/epjconf/20100646002