Larger 5-year migration but similar polyethylene wear of cementless hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) coating compared with porous plasma-spray titanium: a randomized 5-year RSA study

2Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

Abstract

Background and purpose — BoneMaster (BM) is a thin electrochemically applied hydroxyapatite (HA) implant coating marketed with expectations of improved osseointe-gration properties but less polyethylene (PE) wear. We compared the midterm cup migration and PE wear of cementless porous-coated hemispherical cups with and without BM. Patients and methods — In this patient-blinded, randomized controlled trial, 53 patients with a mean age of 64 years (55–75) received total hip arthroplasty with a porous-coated (P) or porous and BoneMaster (PBM) coated Exceed cup and ArCom E1 infused PE. Patients were followed with RSA, Hip Osteoarthritis Outcome Score (HOOS), and Euro-Qol-5-3L (EQ-5D) at 3 and 6 months, and 1-, 2-, and 5-year follow-up. Results — At 5-year follow-up, total translation and maximum total point motion was 0.28 mm (95% CI 0.08; 0.47) and 0.52 mm (CI 0.12; 0.93) higher in the PBM group than in the P group. PE wear was comparable between PBM and P cups, and 2D wear rate from 1 year follow-up to last follow-up was 0.03 mm (CI 0.02–0.03). The 5-year anterior translation was 0.05 mm (CI –0.10 to 0.21) in the normal BMD group and 0.40 mm (CI 0.22–0.57) in the osteopenia group. Interpretation — At 5-year follow-up, Exceed cups in the PBM group migrated more than in the P group but the PE wear rate was low and similar. This study does not indicate any advantage of additional BoneMaster coating compared with porous coating alone on cementless hemispherical cups with regards to migration, polyethylene wear, and clinical outcomes.

Author supplied keywords

Cite

CITATION STYLE

APA

Mosegaard, S. B., Jørgensen, P. B., Jakobsen, S. S., Daugaard, H., Søballe, K., & Stilling, M. (2022). Larger 5-year migration but similar polyethylene wear of cementless hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) coating compared with porous plasma-spray titanium: a randomized 5-year RSA study. Acta Orthopaedica, 93, 658–664. https://doi.org/10.2340/17453674.2022.3976

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free