Sucrose solution as a new viscous test fluid with tunable viscosities up to 2 Pas for micromixing characterization by the Villermaux–Dushman reaction

8Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

For the first time, micromixing characterization for the Villermaux–Dushman reaction could be performed with a non-reactive viscous medium at viscosities up to 2 Pas. As viscous medium, sucrose solution was used with the benefit of being a Newtonian fluid with tuneable viscosity. Due to the higher viscosities in comparison to established media for micromixing investigations, a new protocol for the experimental implementation was developed. Micromixing experiments were conducted and the applicability of viscous sucrose solutions was proven in a stirred tank reactor. Major challenges in characterizing micromixing efficiency in high viscous solution were consolidated.

Cite

CITATION STYLE

APA

Arian, E., & Pauer, W. (2021). Sucrose solution as a new viscous test fluid with tunable viscosities up to 2 Pas for micromixing characterization by the Villermaux–Dushman reaction. Journal of Flow Chemistry, 11(3), 579–588. https://doi.org/10.1007/s41981-021-00158-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free