An optimum study on the laser scanning confocal microscopy techniques for BiFC assay using plant protoplast

4Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The bimolecular fluorescence complementation (BiFC) assay is commonly used for investigating protein–protein interactions. While several BiFC detection systems have been developed, there is a limited amount of research focused on using laser scanning confocal microscope (LSCM) techniques to observe protoplasts. Protoplasts are more susceptible to damage and instability compared to their original cell state due to the preparation treatments they undergo, which makes it challenging for researchers to manipulate them during observation under LSCMs. Therefore, it is crucial to utilize microscope techniques properly and efficiently in BiFC assays. Results: When the target fluorescence is weak, the autofluorescence of chloroplast particles in protoplasts can interfere with the detection of BiFC signals localized in the nuclear region. Spectrum analysis revealed that chloroplast autofluorescence can be excited by lasers of various types, with the highest fluorescence signal observed at around 660 nm. Furthermore, our investigation into the impact of different pipette tips on the integrity of protoplast samples indicated that the utilization of cut tips with larger openings can mitigate cell breakage. We presented a workflow of LSCM techniques for investigating protoplast BiFC and discussed the microscopic manipulation involved in sample preparation and image capturing. Conclusion: When the BiFC signals are weak, they may be affected by chloroplast autofluorescence. However, when used properly, the autofluorescence of chloroplasts can serve as an excellent internal marker for effectively distinguishing other signals. In combination with other findings, this study can provide valuable reference for researchers conducting BiFC assays and related studies.

Cite

CITATION STYLE

APA

Yuan, J., Li, D., Liang, Y., Meng, Y., Li, L., Yang, L., … Li, J. (2024). An optimum study on the laser scanning confocal microscopy techniques for BiFC assay using plant protoplast. Botanical Studies, 65(1). https://doi.org/10.1186/s40529-024-00409-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free